Data Centers – Where Did All the Water Go?
I’d like you to start thinking about how much water your data center uses a day, a month, and a year. Not just for personnel, but for the cooling towers, chiller plants and related IT process applications.
Why worry about water? Well, when more than 1 billion people do not have access to safe drinking water and fully one-third of the world’s population lives in “water stressed” countries, it is time for us to seriously rethink our use of water within our data centers. Water is a life necessity that we must carefully guard and protect in order to ensure our way of life.
As a first step, we need a way to measure water usage in terms of productivity. There has been much discussion around measuring energy usage and productivity in data centers. We need a similar discussion for water usage.
So consider for a moment the ideas of Power Usage Effectiveness, a.k.a. PUE, as defined by The Green Grid, as well as the general concept of productivity, where tangible outputs are related to a unit of input. Now let’s take that idea and tie it to water.
Many people feel that water is the next oil. Though that analogy is probably not the best, it helps us understand water’s value as a unit of measure of productivity. By relating output to water input, we can report, measure and improve data centers’ water productivity and water-use footprints.
It is time for the data center industry to formulate a Water Systems Productivity metric (WSP). Take useful work or even a proxy for useful work, such as the proposed Compute Units Per Second, and divide that by the amount of water used during the period. Water may be measured in units, with 1 unit equal to an acre-foot. However, gallons/liters is also acceptable.
This WSP metric would ideally be reported monthly with your other metrics. Once we start to measure and report water utilization, we will quickly realize that simply flowing more cooling water in order to “economize” may not always be the best answer. Now we will be able to have a meaningful tool to determine the ideal mix between dry-coolers, CW plants and evaporative cooling towers compared to the increased energy used with alternative solutions.
Let’s help the EPA, EU, Green Grid, and others drive a water productivity metric suitable for use within the data center community and a reporting system for rewarding Energy Star-type performance levels.
Jack Pouchet is director of energy initiatives for Emerson Network Power.
Advertisers
Make sustainability part of your strategy.
Get equipped at the SAP Sustainability Resource Center. >>
EFFECTIVELY MANAGE WATER COMPLIANCE
Understand how increased enforcement may affect your company. Find out more >>
EPA mandatory emissions reporting starts Jan 1st
CSA Standards can help your organization get ready for compliance. Find out how. >>
Join the Discussion
Recent Daily News [ see all ]
- 11/06/2009
- 11/05/2009
- 11/04/2009
- Emissions Intensity Falling Globally
- JohnsonDiversey Ups GHG Reduction Target to 25%
- Sainsbury’s Offers Free London Electric Car Charging
- Carbon Trading Could Trigger a ‘Sub-prime Style’ Economic Crash
- Peabody, Exxon Accused of Undermining Climate Talks
- BMW, Toyota, Ford Tout Eco-cars
- In ‘Apathy Gap,’ Energy Efficiency at Home Ranks Low
- China Pushes for CO2 Storage, Not Emissions Reductions
- Clean Tech VC Funding On Rebound, Up 50% Since 2nd Quarter
- IECC Building Code Recommendations Add Up to 30% in Energy Efficiency Gains
- Disney Buys $7M in Reforestation Offsets, a Corporate Record
- McKesson to Save $300K Via Fuel-Efficient Vehicles
- Sprint to Save $2.1M With Eco-Friendly Packaging
- U.S. Export-Import Bank Adopts Carbon Policy to Support Renewable Energy
- Greening the Automotive Supply Chain
- Yokohama Rubber Cuts GHG Emissions 13.4% in 2008
- Electronics Industry Lawsuit Called ‘Attack on States’ Rights’
- Wal-Mart Adding LEDs to 650 Stores
- One Committee Down for Senate Climate Bill, Five More to Go
- EU Poised to Give Heavy Industry Free Carbon Permits
- ResponsibleTravel.com Scuttles Carbon Offsetting Option
- U.S. Cap-and-Trade Creates Winners and Losers among Largest Emitters
- DOE Awards $155M to Make Industrial Sector More Energy Efficient
- System Upgrades Power Up Energy Savings for Hotels
- Xerox Cuts GHG Emissions by 20% from 2002
- Waste Management Landfill Gas Project Complete
- Intel, Pepsi, Kohl’s Stay Atop Green Power Partnership list
- Wal-Mart Thinks Big With Smaller Stores
- Despite Critics, Gore ‘Proud’ to Invest in Green Firms
- Metal Recyclers Spar Over Ship Recycling Site
Industry Voices [ see all ]
A Roadmap for a Renewable Energy Partnership
Brad Cashaw
Vice President
Quaker Foods and Snacks Supply Chain and Sustainability
Forest Carbon Core to Climate Change Deal
Chris Elliott
Forest Carbon Initiative Lead
World Wildlife Fund
VCS and CarbonFix Tops in Review of Forestry Carbon Standards
Paulo Lopes
Carbon Management Consultant
Carbon Clear







Reader Comments
Your suggestion of measuring water consumption soley against compute power is misguided. Unless it takes in account PUE or power consumption of the mechanical systems it will only lead to inefficiency. Direct expansion cooling systems consume several times more power per ton of cooling than evaporative units. I agree we need to be measuring and tracking water consumption of large (>1mw) datacenters. I believe your suggestion of measuring against compute cycles is self serving as Liebert is not competitive with McQuay, Trane, and Carrier for large deployments.
ThinkThank | July 6th, 2009
As it was with PUE, the most immediate value of a metric of any kind is that it gets people to start measuring consumption. If water use is measured it can be managed. I think it is premature, however, to think of this in terms of a productivity metric. The industry is currently struggling with which productivity metric (or proxy) is the best one to use and, until that argument settles out, metrics will be used inconsistently and to game the system. Since the water in question is used to supply cooling, a usable metric will relate water use to either the amount of cooling provided or the amount of electrical power use that is subject to that cooling. Comparing quantity of water used to either the numerator or denominator in the PUE metric would make sense. Gallons of water per watt of power delivered to it’s point of use.
Jud Cooley | July 6th, 2009
Use of water in data-centres is a very North American centric bad-habit. In EMEA (largely for reasons of the health hazards arising from water towers) we tend to use more air-cooled chiller plant in data-centres. The link between data-centres and health is that a local case of legionella can cause a water tower to be immediately shut down by many local health authorities – not condusive to uptime!
Ian Bitterlin | July 7th, 2009
This is an interesting suggestion, but some way ahead of its time. In many geographies and organizations, water use isn’t even metered – that would be a start. Once we have a metric, we would then have a complicated debate – a good metric in power leads to a poorer metric in water, or vice versa. Managers would probably end up with a formula based on financial savings, rather than what is best for the planet or even for the local neighborhood. That isn’t what the EPA or the US intended. Good debate ahead, though.
Andy Lawrence | July 7th, 2009